Off-Gas Fan
The vibration data points indicated rotating looseness and the fan ODE side had a high 2x in the axial position. 2x running speed is an indication of an alignment issue.
The CME recommended checking the bearings and alignment at the next available downtime.
The customer changed out both DE and ODE bearings, which avoided a failure and 64 hours of downtime.